Set the number of inputs in Analyze

Overview

The available options vary based on the measurement type you selected. If you open Analyze from Route, you may be prompted to collect data on the same inputs set for the route point.

Procedure

  1. From the Analyze main menu, press F1 Manual Analyze > F12 Input Setup > F1 Select Input.
    You can also change inputs from an Analysis Expert by pressing F1 Manual Analyze or F1 Setup Menu.
  2. Select one or more inputs.
    Option Description
    F2 Select/Unselect Input A Enable or disable data collection on input A.
    F3 Select/Unselect Input B Enable or disable data collection on input B.
    F4 Select/Unselect Input C Enable or disable data collection on input C.
    F5 Select/Unselect Input D Enable or disable data collection on input D.
    F7 A only Collect input data from input A. If you select this option, the inputs on the left side of the screen automatically update.
    F8 A and B Collect input data from A and B simultaneously. If you select this option, the inputs on the left side of the screen automatically update.
    F9 EmersonTriax Collect data from inputs A, B, and C. If you select this option, the inputs on the left side of the screen automatically update. For the CSI A0643TX triaxial accelerometer, the directions are relative to the sensor: Input A = Z direction, Input B = X direction, Input C = Y direction.
    Note: When you select Emerson Triax, the following sensor options are set for the A, B, and C inputs:
    • Sensor Type = Accelerometer
    • Sensitivity = 0.1
    • Sensor Power = On
    F11 Tach Enable and view the tachometer signals.
  3. Press Enter.
    The active inputs and units display at the bottom of the screen. Disabled inputs are grayed out.