Enable or disable the runout measurement

Overview

Runout is an optional measurement acquired using a displacement sensor during a slow roll of the rotor. A slow roll means the rotor rotates so slowly that readings from the sensors only detect mechanical irregularities on the rotor surface, not vibration. Use runout data to help normalize the balance data.
Note: This is available only in Advanced Balance mode.

Procedure

  1. From the Balance main menu, press F3 Job Setup.
  2. Press Enter or F4 Meas. Plane Setup.
  3. Press F6 Sensor Setup > F11 Toggle Runout.
    Subtract Runout changes each time you press F11 Toggle Runout. By default, Subtract Runout is disabled.